1. Turn upper and lower
adjusting screws one complete revolution
anti-clock wise |
| 2. Release clamp Turn
clamping screws one complete revolution
anti-clockwise |
| 3. Using two allen keys
for opening and tightening the clamp will be
easy |
| 4. Remove blade, clean blade slot |
| 5. Turn the blade over or insert new blade |
| 6. Press blade firmly against adjusting screws and the
rear stop-pin. Tighten clamping screw |
| 7. For rough adjustment, turn the upper and lower
adjusting screws clockwise 3/4 th revolution |
| 8. For accurate measurements a sensitive indicating
micrometer is recommended |
| 9. Check upper and lower setting dimensions (back taper
approx 0.01 mm) |
| 10. Setting fixture is recommended for quick and accurate
size setting. |